A microbrewery is the most honest kind of commercial interior: the product is made in the room, the equipment is the decoration, and the customer can watch the beer being brewed while drinking it. That honesty is also the design challenge. A brewhouse is a wet, hot, heavy industrial space — stainless steel vessels, steam, water, grain, yeast and cleaning chemicals — and it must sit beside a comfortable tasting room where people eat, drink and talk for an evening. The fit-out has to keep those two worlds separate enough to be safe and clean, and open enough that the customer still feels part of the brewing.
Indian microbreweries, often called brewpubs, have grown quickly in cities where the local excise rules allow brewing on the premises. The typical Indian brewpub brews in small batches, serves the beer fresh on tap within days of brewing, and pairs it with a full food menu. That combination — a working brewery, a restaurant and a bar in one building — is what makes the planning demanding. The brewery needs the services of a small factory, the restaurant needs the comfort of a dining room, and the bar needs the theatre of the taps, all under one roof and one licence.
This article works through the fit-out in order: how brewpubs developed, how the brewing and serving flows run, the tank and brewhouse dimensions, the tasting room, the services that keep the brewery safe, the materials that survive a wet industrial floor, and the costs of building one. Dimensions are in millimetres, and costs are indicative October 2026 ranges to be confirmed locally. Licensing is a state subject in India, and the excise rules for brewing on the premises must be checked with the local authority before the design is fixed, because they govern the layout, the storage and the licensed area.
From the village brewery to the Indian brewpub
Brewing is one of the oldest crafts in the world, and for most of its history it was a local trade: small batches, brewed close to where they were drunk, in vessels the brewer could see and touch. The industrial brewery changed that scale, but the craft brewery and then the brewpub brought it back — a small brewery inside a bar, brewing fresh beer for the customers in the room. The brewpub works because freshness is its selling point: beer served days after brewing, with no long storage and no long journey, tastes different, and the customer can see exactly where it came from.
The Indian brewpub adapted that idea to Indian conditions. Indian brewpubs brew lighter, fresher styles that suit a warm climate and a food-led evening, and they pair the beer with a full kitchen rather than bar snacks alone. The brewhouse is usually the visual centre of the room, with polished stainless steel tanks behind glass or on a raised platform, and the tasting room is arranged so every table has a view of the tanks. The brewery also becomes the brand: the names of the beers, the story of the brewing, and the sight of the vessels are the marketing, and the fit-out must show them off rather than hide them in a back room.
The Indian brewpub also faces Indian constraints. Water quality and supply vary by city, and brewing uses a large volume of water for every litre of beer, so water treatment and storage are design decisions, not afterthoughts. Power supply must be reliable for refrigeration and for the brewing process, and a generator or backup supply is a practical necessity rather than a luxury. And the excise rules for brewing on the premises differ by state, govern the size of the brewery, the storage of beer and the licensed serving area, and change from time to time — so the layout must be checked against the current local rules before construction begins.
How a microbrewery actually works: the brewing and serving flows
A microbrewery runs on two flows that must never tangle: the brewing flow and the customer flow. The brewing flow runs from the grain store to the mill, to the brew kettle, to the fermenters, to the serving tanks, and finally to the taps. The customer flow runs from the entrance to the tasting room, to the bar or the table, and back out again. The two flows meet at exactly one point — the tap — and everywhere else they should be kept apart. Grain deliveries, spent grain removal, cleaning chemicals and tank maintenance must all happen from a service route, never through the dining room during trading hours.
The brewing sequence sets the layout. The brewhouse — the kettle and the hot liquor tank — sits where steam can be vented and where the brewer has room to work. The fermenters sit nearby, each one needing working space around it for cleaning and for connecting hoses. The serving tanks sit closest to the bar, because the beer travels from the serving tank to the tap through a short, cold line, and a long beer line is a warm, flat beer. The cold room or cold store sits beside the serving tanks, and the grain store sits near the delivery point, dry and ventilated, away from the wet brewery floor.
The serving flow is simpler but just as important. The taps should be visible from the entrance, because the tap list is the first thing a brewpub customer reads, and the bar should be placed so the queue for a drink does not cross the route to the tables. Glassware moves from the table to a collection point, to the glass washer, and back to the bar, and the glass washer should sit under or beside the bar, not in the brewery. The tasting room needs its own logic too: a customer who has come to taste the beer should be able to order a flight — a set of small glasses of different beers — and the flight should be served on a board or tray that carries safely to the table.
| Flow | Route | What goes wrong if it is not planned |
|---|---|---|
| Brewing | Grain store, mill, kettle, fermenter, serving tank | Long beer lines; warm, flat beer |
| Customers | Entrance, tasting room, bar, table | Queue crosses the table service route |
| Glassware | Table, collection, washer, bar | Washer in the brewery; slow turnaround |
| Supplies | Service route, grain store, brewery | Deliveries through diners |
| Waste | Spent grain, cleaning water, drains | Wet floors; blocked gullies |
Tanks, taps and the brewhouse: the numbers that matter
The tank is the unit of the brewery, and its size decides the room. A typical Indian microbrewery uses fermenters and serving tanks of about 1,000 to 1,500 mm in diameter and 1,800 to 2,800 mm in height, with a capacity of roughly 500 to 2,000 litres each. Each tank needs 900 mm of clear working space around it for cleaning, for connecting hoses and for reading gauges, and the floor beneath must be level and strong enough to carry a full tank — a 1,000-litre tank weighs about a tonne of beer plus the steel, and the floor loading must be checked by the structural engineer, not assumed. The ceiling over the tanks must be high enough for the tank plus the working space above it: a brewhouse ceiling of 4,500 to 6,000 mm is typical, and the tanks should be drawn in section before the ceiling height is fixed.
The brew kettle and the hot liquor tank sit together as the brewhouse, and they need steam or direct heat, a vent to the outside, and a water supply that can fill them quickly. The kettle is usually the largest single vessel, and it needs a platform or a raised plinth so the brewer can work at a comfortable height and so the floor beneath can be cleaned. The mill and the grain store sit nearby but dry: grain must be kept dry and ventilated, and the mill creates dust, so it should be separated from the wet brewery floor by a wall or a screen. The cold room or cold store holds the serving tanks or the kegs at serving temperature, and its door should open toward the bar, not away from it.
The taps are where the brewery meets the customer, and they deserve the same care as the tanks. A tap tower carries 4 to 12 taps, each one a short, cold beer line from the serving tank, and the tower should sit on a bar counter 1,050 to 1,100 mm high, the same as any bar counter. The drip tray beneath the taps must drain, not just collect, and the glass washer and the glass storage should sit within the bartender's reach. The tap list should be displayed where the queue can read it — a board above the bar at 1,600 to 1,800 mm centre height — and the beer names and styles should be written plainly, because a customer who cannot read the list will order the beer they already know.
| Brewery element | Typical size | Notes |
|---|---|---|
| Fermenter or serving tank | 1,000–1,500 mm diameter | 500–2,000 litres each |
| Tank height | 1,800–2,800 mm | Plus working space above |
| Working space around tank | 900 mm clear | Cleaning, hoses and gauges |
| Brewhouse ceiling | 4,500–6,000 mm | Draw the tank in section first |
| Bar counter height | 1,050–1,100 mm | Same as any bar counter |
| Tap tower | 4–12 taps | Short, cold line from serving tank |
| Tap list board centre | 1,600–1,800 mm high | Readable over a queue |
The tasting room: where the beer is sold
The tasting room is a bar and a restaurant that happens to have a brewery in it, and it should be planned as a comfortable room first and a showcase second. Tables for two at 600 to 750 mm square and tables for four at 750 by 900 mm suit the food-led Indian brewpub, with a few high tables near the bar for customers who have come for a quick drink. The bar itself should be 6,000 to 9,000 mm long for a mid-size brewpub, with stools at one per 600 to 700 mm of counter. The viewing glass between the tasting room and the brewhouse is the most important wall in the building: it should be full height where possible, kept clean, and lit from the brewery side so the tanks glow, not from the tasting-room side, which would turn the glass into a mirror.
The tasting experience is what brings customers back, and the design should support it. A flight of small glasses — typically four glasses of about 100 to 150 ml each — lets a customer taste the range, and the flight board should be served on a tray that a server can carry safely. The menu should describe each beer in plain words — light or dark, bitter or malty, strong or session — rather than in brewing jargon, because most customers are tasting, not studying. A small retail shelf near the exit, with bottles, growlers or merchandise, turns a good evening into a take-home sale, but it should not block the exit route.
The tasting room also needs the practical comforts of any dining room: a ceiling of at least 3,000 to 3,600 mm, warm light at 50 to 150 lux at the tables and brighter light at the bar, acoustic treatment so people can talk, and a clear route to the toilets that does not pass through the brewery. The toilets themselves should be sized for a full room, with one water closet per 25 to 30 customers as a rough guide and separate facilities for men and women, and they should be reachable without crossing the brewing floor. Children and non-drinking customers are part of an Indian brewpub evening, so the food menu and the non-alcoholic drinks deserve the same care as the beer list.
| Tasting room item | Typical size | Planning rule |
|---|---|---|
| Bar length, mid-size brewpub | 6,000–9,000 mm | Stools one per 600–700 mm |
| Table for two | 600–750 mm square | Height 720–750 mm |
| Table for four | 750 × 900 mm | Shared food and flights fit |
| Tasting flight | Four glasses, 100–150 ml each | Served on a board or tray |
| Main aisle | 1,800–2,400 mm | Two people carrying trays pass |
| Ceiling height | 3,000–3,600 mm | Comfort and acoustics |
| Viewing glass | Full height where possible | Lit from the brewery side |
Layouts that fit real Indian sites
Three layouts cover most Indian microbreweries. The first is the small brewpub: a brewhouse of two to four tanks, a bar of 4,000 to 6,000 mm, seating for 40 to 60 people, and a total area of about 250 to 400 sq m. It suits a high-street or mall site where the brewing is the attraction and the food menu is short. The brewhouse sits behind glass at one end, the bar sits in front of it, and the tables fill the rest of the room. The risk is a brewhouse that is too small to keep up with a busy weekend, so the tank count should be sized against the busiest week, not the average one.
The second is the mid-size brewery bar: four to eight tanks, a bar of 6,000 to 9,000 mm, seating for 80 to 120 people, and about 450 to 700 sq m. This is the common Indian brewpub: a full kitchen, a proper tasting room, a retail shelf and a small outdoor area. The brewhouse sits along one wall behind glass, the bar sits opposite it or in front of it, and the tables sit between the two, so every seat has a view of either the bar or the tanks. The back of house — grain store, cold store, cleaning store and staff area — should be about 20 to 25 per cent of the total area, reached from a service corridor.
The third is the large brewhouse with a taproom: eight or more tanks, a brewhouse that is a destination in itself, guided tours, a large taproom and an outdoor area, and 800 sq m or more. At this scale the brewery needs its own entrance for deliveries and its own loading area, and the taproom needs zoning: a lively area near the bar and a quieter area for dining. The brewery floor should be designed as an industrial floor from the start — falls to gullies, chemical-resistant finishes, and a ceiling high enough for a forklift or a hoist where the tanks are installed — because retrofitting an industrial floor into a finished restaurant is expensive and disruptive.
| Layout | Tanks | Seats | Total area |
|---|---|---|---|
| Small brewpub | 2–4 | 40–60 | 250–400 sq m |
| Mid-size brewery bar | 4–8 | 80–120 | 450–700 sq m |
| Large brewhouse and taproom | 8 or more | 120–200 | 800 sq m or more |
| Back of house share | Grain, cold, cleaning, staff | — | 20–25 per cent of total |
| Brewhouse ceiling | 4,500–6,000 mm | — | Check tank height first |
Water, drainage, steam and safety: the services that decide success
A brewery is a water business as much as a beer business. Brewing, cleaning and cooling use a large volume of water, and the water supply, treatment and storage must be sized for the peak brewing day, not the average one. A water treatment plant or filtration unit is usually needed, because the mineral content of the water affects the taste of the beer, and the treated water should be stored in a dedicated tank so a municipal supply interruption does not stop a brew. Hot water is needed in large volumes for cleaning, so the hot-water system should be sized with the brewer, and the steam or heating system for the kettle must be vented safely to the outside.
Drainage is the service that most often fails in a brewery fit-out. The brewery floor must fall gently to trapped gullies, the gullies must be sized for the volume of water used in cleaning, and the drains must be trapped and vented so smells do not come back into the room. Spent grain and cleaning chemicals must never go down a standard drain: spent grain is collected separately, and cleaning chemicals must be neutralised or disposed of according to the local rules. The floor finish must resist both water and chemicals — a resin or epoxy floor, or a chemical-resistant tile with epoxy grout — because a standard tile grout will fail within months under brewery cleaning.
Safety in a brewery is governed by the same principles as any industrial space, plus the rules for alcohol. Carbon dioxide, which is produced during fermentation, is heavier than air and can collect in low areas, so the brewhouse needs ventilation at low level as well as at high level, and a carbon-dioxide monitor is a sensible precaution in any enclosed brewery. Steam and hot water need guarded pipework and clear warning signs. The gas supply, where used, needs a leak detector and a shut-off valve. Fire safety follows the National Building Code: clear exits, illuminated signs, extinguishers, and a fire alarm linked to the building system. The liquor storage must be lockable, and the licensed area must be drawn on the plan and approved under the local excise rules.
| Service | Typical provision | Why it matters |
|---|---|---|
| Water supply | Treated, stored, sized for peak brew day | Water quality decides beer taste |
| Drainage | Falls to trapped gullies, 1 in 60 | Cleaning water clears fast |
| Floor finish | Resin, epoxy or chemical tile | Resists water and cleaning chemicals |
| Ventilation | Low and high level, plus steam vent | Carbon dioxide is heavier than air |
| Fire safety | Exits, signs, extinguishers, alarm | National Building Code requirements |
| Power backup | Generator for refrigeration and brewing | A power cut must not spoil a brew |
Materials, finishes and cleaning: built to survive a wet brewery
The brewery floor is an industrial floor, and it must be specified as one. A resin or epoxy floor, or a chemical-resistant tile with epoxy grout, laid to falls toward trapped gullies, is the usual answer, with coved skirting where the floor meets the wall so water and cleaning chemicals do not seep into the base. The tasting-room floor can be warmer — timber, tile or sealed concrete — but the threshold between the brewery and the tasting room should be a clear line, with a change of material and a drain or a mat well, so brewery water does not travel into the dining room on feet and wheels.
Walls in the brewery should be washable to full height where they are splashed, whether that is tile, a resin coating or stainless steel sheet behind the tanks and the kettle. The tasting-room walls can be warmer — timber, plaster or brick — but the dado to 1,200 mm should still be washable, because chairs, trays and bags scuff it. Stainless steel is the material of the brewery itself: tanks, pipework, worktops and sinks should all be food-grade stainless steel, and the steel should be specified by grade, not by appearance, because a lower grade will stain and pit under brewery cleaning chemicals.
Cleaning in a brewery is a daily discipline, and the plan should make it easy. The brewery needs a dedicated cleaning store with a floor drain, a hose point, a shelf for chemicals kept away from grain and beer, and a clear procedure written on the wall. The tasting room needs the same cleaning logic as any restaurant: a mop sink, a cleaning store close to the bar, and a floor that can be washed nightly. Waste needs separate streams: spent grain collected for disposal or for animal feed where the local rules allow, glass and general waste separated, and cleaning chemicals disposed of according to the local rules, never down a standard drain.
Costs, phasing and the opening checklist
Microbrewery costs split into the building fit-out, the brewing equipment, and the bar and kitchen. As an indicative October 2026 range, the building fit-out — flooring, ceiling, lighting, air conditioning, tasting-room seating and the bar — typically runs about ₹2,500 to ₹4,500 per sq ft. The brewing equipment — kettle, fermenters, serving tanks, cooling, water treatment and pipework — typically runs about ₹80 lakh to ₹2.5 crore for a small to mid-size brewery, depending on the tank count and the degree of automation. A 500 sq m mid-size brewpub therefore commonly totals about ₹2.5 crore to ₹5 crore all in, excluding rent, licences and the initial stock.
Phasing should protect the two longest timelines: the brewing equipment, which is often imported or made to order and can take months, and the excise licence, which can require changes to the plan. The equipment should be ordered before construction starts, and the tank sizes and ceiling heights should be confirmed with the equipment supplier before the structure is fixed. Construction should run services first — water, drainage, power, steam and ventilation — then the brewery floor and the tanks, then the tasting room, and finally the bar and kitchen. The opening checklist should include a full trial brew, a trial service at full volume, and a check that the beer lines, the glass washer and the cold store all hold temperature under load, because a warm beer on opening night is a review that never goes away.
| Cost item | Indicative range, October 2026 | Notes |
|---|---|---|
| Building fit-out | ₹2,500–4,500 per sq ft | Floor, ceiling, light, air, seating, bar |
| Brewing equipment | ₹80 lakh–2.5 crore | Kettle, tanks, cooling, water treatment |
| Bar and kitchen equipment | ₹15,00,000–40,00,000 | Taps, coolers, washer, kitchen line |
| 500 sq m brewpub, all in | ₹2.5 crore–5 crore | Excluding rent, licences, stock |
| Tasting flight board | ₹500–1,500 each | Boards, small glasses, trays |
Eight rules for a microbrewery that earns
These rules are the ones to check on the plan before construction, when the tanks are still a drawing and every change is still cheap.
- Size the tanks against the busiest week, not the average week, and leave 900 mm of working space around each one.
- Keep the beer line short and cold: serving tanks close to the bar, and a cold room that holds temperature under load.
- Check the floor loading with a structural engineer before ordering a single tank.
- Draw the ceiling height from the tank section: a brewhouse needs 4,500 to 6,000 mm, not a standard restaurant ceiling.
- Fall the brewery floor to trapped gullies and specify a resin or epoxy finish that resists cleaning chemicals.
- Ventilate at low level as well as high level, because carbon dioxide is heavier than air.
- Check the excise licence and the licensed area before construction, and order the brewing equipment early.
- Light the tanks from the brewery side of the viewing glass, and keep the glass clean — the beer is the display.
Frequently asked questions
How much does it cost to open a microbrewery in India?
As an indicative October 2026 range, the building fit-out runs about ₹2,500 to ₹4,500 per sq ft and the brewing equipment runs about ₹80 lakh to ₹2.5 crore for a small to mid-size brewery. A 500 sq m mid-size brewpub commonly totals about ₹2.5 crore to ₹5 crore all in, excluding rent, licences and stock. Licence fees vary widely by state, so confirm them locally before budgeting.
How much space does a microbrewery need?
A small brewpub with two to four tanks and 40 to 60 seats needs about 250 to 400 sq m. A mid-size brewery bar with four to eight tanks and 80 to 120 seats needs about 450 to 700 sq m. The brewhouse ceiling must be 4,500 to 6,000 mm high, and the back of house — grain store, cold store, cleaning store and staff area — should be 20 to 25 per cent of the total area.
What size are brewery tanks?
Typical microbrewery fermenters and serving tanks are about 1,000 to 1,500 mm in diameter and 1,800 to 2,800 mm high, holding roughly 500 to 2,000 litres each. Each tank needs 900 mm of clear working space around it, and the floor beneath must be checked by a structural engineer for the weight of a full tank.
Do I need a licence to brew beer in India?
Yes. Brewing and serving alcohol is licensed by the state excise authority, and the rules on brewery size, storage and the licensed serving area differ by state and change from time to time. Start the licence application before construction, because it can require changes to the layout, and confirm the current rules with the local authority.
What is a tasting flight?
A tasting flight is a set of small glasses — typically four glasses of about 100 to 150 ml each — of different beers, served together on a board or tray so the customer can compare them. It is the best way for a first-time customer to find the beer they like, and the menu should describe each beer in plain words rather than brewing jargon.
Can customers see the brewery while they drink?
Yes, and they should. A full-height viewing glass between the tasting room and the brewhouse, lit from the brewery side so the stainless steel tanks glow, is the centrepiece of a brewpub. The glass must be kept clean, and the brewery side must be kept tidy, because the customer is looking at the working brewery, not a picture of one.
Sources & standards
- Bureau of Indian Standards — National Building Code of India 2016, Part 4 (Fire and Life Safety) and Part 8 (Building Services, Section 1: Lighting and Ventilation)
- Bureau of Indian Standards — IS 732:2019, Code of practice for electrical wiring installations
- Bureau of Indian Standards — IS 3043:2018, Code of practice for earthing
- Neufert, Ernst — Neufert Architects' Data, 4th edition: dimensions for industrial and hospitality spaces
- Time-Saver Standards for Interior Design and Space Planning, 2nd edition: food-service and commercial planning data
- State excise rules and liquor licensing requirements — check the current rules of the state where the business operates
- Food Safety and Standards Authority of India — Food Safety and Standards Act and licensing guidance for food businesses
- Price ranges: indicative October 2026 estimates — confirm locally before budgeting