← All articles

Lighting · 10 Nov 2026 · 20 min read

Gas Pipeline and PNG Planning for Kitchens

Gas Pipeline and PNG Planning for Kitchens — cover

For generations the Indian kitchen was planned around a red cylinder: a heavy LPG bottle under the counter, a rubber tube to the hob, and the monthly ritual of booking a refill and heaving the replacement into place. Piped natural gas, now reaching city after city, quietly removes that cylinder. Gas arrives through a pipe from the street, past a meter, to a point beside the hob, and the household simply pays for what it burns. But the convenience hides a planning task, because gas is the one kitchen service where a careless detail is not merely untidy but dangerous. A pipe run too close to an electrical point, a gas point hidden behind a built-in oven, or a kitchen sealed tight for air-conditioning without a vent are the mistakes that turn a clean utility into a hazard.

Planning gas well means thinking about it before the kitchen is designed, not after. The route from the building's riser to the hob, the material of the pipe, the height and position of the gas point, the clearances from electrical switches and sockets, and above all the ventilation of the room must all be set while the kitchen layout is still on paper. Retrofitting a gas point into a finished modular kitchen is possible but awkward, often leaving an exposed pipe snaking across a beautiful counter. The households that are happiest with PNG are those whose kitchen and gas were planned together, so the pipe is concealed, the point is exactly where the hob sits, and the room breathes.

This article treats the kitchen gas supply as a planning problem. It explains the route and the players — the distribution company, the riser, the meter and the appliance — the pipe materials and sizes used in India, the standard heights and clearances that keep the installation safe and tidy, the differences between LPG and PNG that matter to a kitchen designer, and the indicative October 2026 costs. It is written for the homeowner planning a kitchen, with enough detail to coordinate the gas work with the carpentry and the electrical layout rather than leaving each trade to fight the others on site.

A short history of the kitchen gas supply

The Indian kitchen's fuel has changed within living memory. Firewood and the kerosene stove gave way, from the 1950s onwards, to liquefied petroleum gas in steel cylinders — a transformation that made cooking cleaner and faster and that still serves the majority of Indian homes. The cylinder, booked and delivered, became a fixture of domestic life and of kitchen design, which had to find a ventilated cupboard to hide it. For decades that was simply how a kitchen worked: a bottle, a regulator, a rubber tube and a flame.

Piped natural gas is the newer chapter. Natural gas, mostly methane, is distributed by pipeline to homes as a continuous supply, metered like water or electricity, under the oversight of the national regulator for petroleum and natural gas. City gas distribution networks have spread rapidly across Indian towns, and new apartment projects are increasingly built PNG-ready, with the riser and meter positions designed in from the start. The appliance barely notices the change — a hob is converted from LPG to PNG by swapping the small injector nozzles, because natural gas burns at a different pressure — but the kitchen changes a great deal: the cylinder cupboard disappears, freeing storage, and the supply never runs out mid-meal. The direction is clear: where the pipeline reaches, the cylinder retreats.

Fig. 1 — From cylinder to pipeline over time Mid 1900sfirewood andkerosene stove 1960s–onLPG cylinderbooked, delivered 2000s–onPNG networksspread to cities NowPNG-ready flats,metered supply Piped gas removes the cylinder from the kitchen and meters the supply like water — but the hob only needs its injector nozzles changed, because natural gas burns at a different pressure from LPG.
Fig. 1 — From cylinder to pipeline: the kitchen gas supply over time

How piped gas reaches the kitchen

A PNG connection is a chain, and understanding it helps a homeowner coordinate the work. Gas travels from the city distribution network's main in the street, through a service pipe into the building, and up a riser — a vertical pipe serving each floor. At the flat, it passes through an isolation valve and a meter, which records consumption, and then through the home's own pipe to the gas point beside the hob. Each stage has an owner: the distribution company is responsible up to and including the meter, and the householder's installation begins after it. The appliance valve at the hob, which the user turns on and off, is the last link, and a master valve near the meter lets the whole flat be isolated in an emergency.

Fig. 2 — Gas route: riser and meter to the hob point riser meter sink counter run hob concealed gas pipe along wall master valve The pipe runs from the meter along the wall to the hob, concealed in a chase or a conduit, with the hob point exactly where the cooking range sits. An appliance valve at the hob and a master valve at the meter let the gas be shut off.
Fig. 2 — PNG route from riser to hob (plan, mm)

The design lesson is to fix the meter and hob positions early and keep the pipe run between them short, direct and concealable. A gas point is most useful at the back of the hob location, so the flexible connector to the cooktop is short and hidden. Where the kitchen has an island hob, the pipe must reach it through the floor or a bulkhead, which is far easier to plan before the slab and cabinetry are built than to improvise afterwards. The pipe should run where it can be inspected or accessed if needed, not buried irretrievably, and it must never share a chase with electrical cables.

Pipe materials, sizes and the connection to the hob

Gas pipework in Indian homes is most often galvanised iron (GI) or, increasingly, copper, with the final short link to the appliance made by an approved flexible hose. The distribution company specifies and usually installs the pipe up to the appliance valve, to its own standard, so the homeowner's job is mainly to plan the route and provide a concealed, accessible path. What a designer should know is that gas pipe is not improvised like a water line: joints are made to a gas-tight standard, the whole installation is pressure-tested before use, and only approved materials and fittings are permitted. The flexible connector between the fixed point and a movable cooktop is a wear item with a limited life and should be a proper gas-rated hose, not a general rubber tube.

ElementTypical choiceNote
Riser and service pipeSteel / GI, by the gas companyCompany's responsibility to the meter
In-home concealed pipeGI or copper, approved gradeRouted along walls, pressure-tested
Appliance isolation valveBrass gas valve at the hobUser shuts this off after cooking
Connector to cooktopApproved flexible gas hoseA wear item; replace within its rated life
Master valveNear the meterIsolates the whole flat in an emergency

Sizing the pipe is the gas company's calculation, based on the appliances to be served and the length of the run, so that enough gas reaches the hob at the right pressure even with every burner lit. For a normal home kitchen with a four-burner hob this is a modest pipe; a home adding a gas oven, a gas water heater or a second cooking point needs the demand assessed so the pipe is not undersized. The practical point for the homeowner is to declare all intended gas appliances at the planning stage, because adding a gas geyser later to a pipe sized only for a hob may mean reworking the supply.

Heights, clearances and kitchen ventilation

Gas is the service where clearances are safety, not neatness. The gas point sits at a sensible working height beside the hob, the pipe keeps a clear distance from electrical switches, sockets and the consumer unit, and — most important of all — the kitchen must be ventilated. A gas flame consumes oxygen and produces combustion products, and any leak of unburnt gas must be able to disperse rather than collect. A modern kitchen sealed for air-conditioning, with sleek handleless cabinets and no openable window, is exactly the kind of room where a gas leak becomes dangerous. Permanent ventilation — an openable window, a louvre, or a vent high and low — is a requirement of safe gas practice, not an optional comfort.

Fig. 3 — Gas point and clearances at the hob (elevation) chimney / hood hob counter 850 gas pointabout 350–500 hood 650–750above hob gas point socket keep the gas point well clear of electrical sockets and switches — never share a chase
Fig. 3 — Gas point height and clearances at the hob (elevation, mm)

The usual arrangement puts the gas point low beside or behind the hob base unit, roughly 350 to 500 mm above the floor so it clears the skirting and sits below the counter, with the appliance valve reachable. The chimney or hood above the hob is set 650 to 750 mm above the cooktop so it captures fumes without being in the cook's way. Electrical points — sockets for the microwave, the chimney and small appliances — are kept to one side, clear of the gas point and the pipe, so a gas leak can never meet a switch spark. These are not arbitrary numbers but the everyday grammar of a safe kitchen, and they are far easier to honour when the gas, the electrical and the cabinetry are drawn on one elevation.

ItemTypical dimensionWhy
Hob counter height850 – 900 mmComfortable Indian cooking height
Gas point above floorAbout 350 – 500 mmBelow counter, clears skirting, valve reachable
Chimney / hood above hob650 – 750 mmCaptures fumes without blocking the cook
Clearance, gas point to socketKeep well separatedGas must never meet an electrical spark
Kitchen ventilation openingPermanent, high and lowLets a leak disperse and feeds the flame air
Fig. 4 — Why a gas kitchen needs a high and a low vent high vent low vent hob fresh air in low products rise and leave high A low vent feeds the flame fresh air; a high vent lets warm combustion products and any leak of gas escape rather than
Fig. 4 — Kitchen ventilation for gas safety (section, mm)

LPG or PNG: what matters to a kitchen designer

Where both are available, the choice between a cylinder and a pipe affects the kitchen's design as much as its running cost. LPG needs a ventilated cupboard for the cylinder and the inconvenience of refills, but works anywhere and needs no network. PNG frees that cupboard for storage, never runs out mid-meal, is billed by use, and removes the heavy cylinder from the home — but is available only where the network reaches, and ties the kitchen to a fixed meter and riser position. For a designer the practical differences are a short list, set out below; for safety both are handled with the same respect, since both are flammable gases that demand ventilation and clearances.

PointLPG (cylinder)PNG (pipeline)
SupplyBooked cylinders, can run outContinuous, metered like water
Kitchen spaceNeeds a ventilated cylinder cupboardFrees that space for storage
AvailabilityAnywhereOnly where the network reaches
Cooktop changeStandard LPG nozzlesInjector nozzles swapped for lower pressure
BillingPer cylinderPer unit consumed, monthly

One technical point is worth stating plainly, because it causes confusion: an LPG hob and a PNG hob are not different appliances, but they are not interchangeable without a small change. Natural gas is supplied at a lower pressure than LPG, so the tiny injector nozzles in each burner must be changed when converting a hob from one to the other. This is a quick job for the gas technician, but it means a household switching to PNG keeps its cooktop and simply has it converted, rather than buying a new one — a useful thing to know before replacing a perfectly good hob.

What a PNG installation costs

PNG costs fall into a one-time connection and setup, and the ongoing metered gas. The figures below are indicative October 2026 ranges for the Indian market, intended only to set expectations; the distribution company publishes its own connection charge and security deposit, and the in-home pipework beyond the meter depends on the run and the number of points. A kitchen designer's concern is mainly the installation and concealment cost, since the gas commodity is billed monthly thereafter. The one-time outlay is modest against the convenience of losing the cylinder, and the running cost is generally competitive with LPG for a typical household.

ItemIndicative cost (October 2026)Note
PNG connection charge + security deposit₹5,000 – ₹8,000Set by the distribution company; deposit refundable
In-home pipework (meter to one hob point)₹2,000 – ₹6,000Depends on run length and concealment
Additional gas point (oven / second hob)₹2,000 – ₹5,000 eachDeclare all appliances at planning
Hob conversion (LPG to PNG nozzles)₹300 – ₹1,000Keep the existing cooktop
Approved flexible gas hose₹300 – ₹900A wear item; replace within rated life
Metered gas (running cost)Per unit consumed, monthlyGenerally competitive with LPG

Where kitchen gas is going next

Two currents are shaping the kitchen's gas future. The first is the continued spread of PNG networks, making the piped supply the default in new urban housing and steadily retiring the cylinder cupboard from kitchen design. Apartment projects are increasingly delivered PNG-ready, with risers, meters and gas points planned into the base building, so the kitchen designer inherits a fixed point to work around rather than a cylinder to hide. The second current is electrification: the induction cooktop, fast and flameless, is winning a share of Indian kitchens, especially as a second cooking point, and some households are designing kitchens that can run on either gas or electricity. The likely outcome is not one fuel but a hybrid kitchen — a piped gas point for the cooking that suits a flame, and an induction point for speed and for the days the gas is off. Whatever the mix, the planning discipline holds: fix the points early, keep gas clear of electrics, and let the room breathe.

Nine rules for planning kitchen gas

  • Fix the meter and hob positions early, and keep the pipe run between them short, direct and concealable.
  • Declare every intended gas appliance at the planning stage so the pipe is sized for the full demand, not just one hob.
  • Use only approved pipe, fittings and a gas-rated flexible hose — gas pipework is never improvised like a water line.
  • Keep the gas point and pipe well clear of electrical switches, sockets and the consumer unit, and never share a chase.
  • Set the gas point about 350 to 500 mm above the floor beside the hob, with the appliance valve easy to reach.
  • Ventilate the kitchen permanently — an openable window or vent high and low — especially in a sealed, air-conditioned kitchen.
  • Have the installation pressure-tested and commissioned by the gas company before use, and keep the pipe accessible for inspection.
  • Turn off the appliance valve after cooking, and know where the master valve is for an emergency.
  • On a smell of gas, use no sparks, switches or flames — shut the master valve, open up, and call the emergency line.

Frequently asked questions

Can I keep my existing hob when switching to PNG?

Yes. A gas hob is converted from LPG to PNG by swapping the small injector nozzles in each burner, because natural gas is supplied at a lower pressure. It is a quick job for the gas technician and costs far less than a new cooktop, so there is usually no need to replace a working hob when a PNG connection arrives.

How high should the gas point be in a kitchen?

The gas point usually sits about 350 to 500 mm above the floor, beside or behind the hob base unit, so it clears the skirting, stays below the counter and leaves the appliance valve within easy reach. The exact height is coordinated with the cabinetry; what matters is that the point is near the hob, the pipe run is short, and the valve can be turned off without moving the cooker.

Is PNG safe in a closed, air-conditioned kitchen?

Only if the kitchen is still ventilated. A gas flame needs air and any leak must be able to disperse, so a sealed, air-conditioned kitchen must have permanent ventilation — an openable window, a louvre, or vents high and low. A gas-leak detector adds a useful warning in such a room. Sealing a kitchen tight for air-conditioning without any vent is unsafe with any gas, LPG or PNG.

Who is responsible for the gas pipe in my flat?

The city gas distribution company is responsible for the supply up to and including the meter, and usually installs the in-home pipe up to the appliance valve to its own standard. The householder's duties are to plan an accessible, concealed route, declare all appliances, maintain the flexible hose, and use the installation safely. Any alteration to the gas pipe should be done by the company or its approved technician, never by a general plumber.

Can one pipe feed a hob and a gas water heater?

Yes, provided the pipe is sized for the combined demand. This is why every intended gas appliance should be declared at the planning stage: a pipe sized only for a four-burner hob may be undersized for a hob plus a gas geyser running together. Assessing the demand up front avoids reworking the supply later to add a second appliance.

Sources & standards

  1. Petroleum and Natural Gas Regulatory Board (PNGRB) — general guidance on city gas distribution and piped natural gas
  2. Bureau of Indian Standards — IS codes for gas pipe installation, fittings and domestic gas appliances
  3. National Building Code of India 2016, Part 8 — Building Services (gas supply and ventilation)
  4. National Building Code of India 2016, Part 9 — plumbing and allied services where gas routing is coordinated
  5. Neufert Architects' Data — kitchen planning, appliance clearances and ventilation
  6. Price ranges: indicative October 2026 estimates — confirm with the local city gas distribution company before budgeting
Discuss your project