A door is the single most-used moving part in any Indian home. It is opened and shut dozens of times a day, pulled by the monsoon draught, leaned on by children and loaded with the weight of a full-length mirror or a row of hooks. Yet of every element in a fit-out, the door is the one most often ordered by a rough nominal size — a casual "seven by three" — without anyone checking the frame section, the shutter thickness, the swing clearance or the gap under the leaf. The result is a door that binds in summer, rattles in winter, or scrapes a freshly laid floor within months of being hung.
The confusion begins with the fact that three different measurements all get called the door size. There is the structural opening left in the wall, the frame or chowkat that is fixed into that opening, and the shutter or leaf that actually swings. A carpenter quoting "900 by 2100" may mean the shutter, the outer face of the frame, or the masonry opening, and a fifty-millimetre misunderstanding at that stage reappears later as a door that will not accept a standard handle set, or a wardrobe that no longer fits in the space beside it.
This article sets out the sizes that Indian homes actually use, the Indian Standard codes that sit behind them, and the frame and shutter details that decide whether a door lasts twenty years or starts sticking in its second monsoon. It covers entrance doors, bedroom and bathroom doors, the chowkat profile and its rebate, shutter types and thicknesses, the clearances that must be left, and indicative October 2026 costs for the materials used most often across the country.
Where Indian door sizes come from
Door sizes in India grew out of carpentry before they were ever written into a code. For generations, frames were cut from sawn hardwood sections a carpenter could lift and plane by hand, and shutters were panelled in solid timber whose stiles and rails had to be thick enough not to warp. The seven-foot height — close to 2100 millimetres — settled in because it cleared the tallest person comfortably while keeping the shutter small enough to stay flat. The widths followed use: a wide leaf for the main entrance where furniture and people pass, a medium leaf for rooms, and a narrow leaf for the bathroom, where space is tight and privacy, not passage, is the point.
Two layers of standardisation were later laid over this craft tradition. The Bureau of Indian Standards published dimensions for timber door and window frames in IS 4021 and for panelled and glazed timber shutters in IS 1003, with flush door shutters covered by IS 2202; these codes fix preferred sizes, section profiles and quality tests rather than dictating a single door for every home. Above them sits the National Building Code of India 2016, whose Part 3 on development control sets minimum clear widths for doors so that rooms remain usable and escape remains possible. The modern Indian door is the meeting point of all three: trade habit, IS dimensions and NBC minimums.
Opening, frame and shutter: three sizes that must agree
Before any size is quoted it helps to name the three measurements precisely. The structural opening is the gap left in the masonry; it is the largest of the three and is sized to receive the frame plus a packing gap for plumbing the frame true. The frame, or chowkat, is the fixed timber or WPC surround that is anchored into the opening and carries the hinges. The shutter is the leaf that swings; its size is the clear opening the door gives when open. A clean rule keeps them in order: the masonry opening is the frame outer plus roughly 10 to 15 millimetres all round for packing, and the shutter is the frame inner (the rebate line) less a 3 millimetre working gap on the hinge and lock sides.
The table below lists the sizes Indian homes settle on in practice. Heights cluster tightly at 2100 millimetres, with taller 2250 to 2400 millimetre leaves chosen in premium work for a sense of height. Widths vary by room and by the use the opening must carry: the main door must pass a sofa and two people abreast, while a bathroom door needs only one person. The NBC minimum clear width for a habitable-room door is 900 millimetres and for a bathroom or water-closet 750 millimetres, so the compact bathroom figure should be read as a dimension used where space is genuinely tight, with 750 millimetres preferred wherever it can be managed.
| Door | Shutter width (mm) | Height (mm) | Shutter thickness | Notes |
|---|---|---|---|---|
| Main / entrance (single) | 1000–1200 | 2100 (to 2400) | 35–40 mm | Wide leaf; heavier hinges and a stout frame |
| Main / entrance (double) | 1200–1500 total | 2100 (to 2400) | 35–40 mm | Two leaves of 600–750 mm each |
| Bedroom | 800–900 | 2100 | 32–35 mm | 900 mm reads generous; 800 mm acceptable |
| Kitchen | 800–900 | 2100 | 32–35 mm | Match bedrooms for a tidy run of doors |
| Bathroom / WC | 600–750 | 2100 (or 2000) | 30–32 mm | 750 mm preferred; 600 mm only where very tight |
| Store / utility | 600–750 | 2100 | 30–32 mm | Often a lighter flush leaf |
| Pooja room | 600–900 | 2000–2100 | 30–35 mm | Paired shutters common; sized to the niche |
Inside the frame: the chowkat and its rebate
The frame carries the door, so its section decides how solid the door feels. A common hardwood chowkat is cut to about 100 by 65 millimetres for internal doors and 125 by 70 millimetres for a heavy main door, with a rebate — a stepped notch — cut along the inner edge so the shutter closes into it and seals against draught and light. The rebate depth is set a few millimetres deeper than the shutter is thick, usually 15 millimetres for a 32 millimetre leaf, so the shutter sits flush without proud edges. A frame fixed with holdfasts or anchor fasteners into the masonry, and a shutter that beds cleanly into a true rebate, is the difference between a door that shuts with a soft click and one that has to be pushed.
| Frame use | Section (mm) | Rebate depth | Fixing | Material choices |
|---|---|---|---|---|
| Internal door frame | 100 × 65 | 15 mm | Holdfasts / screws to plug | Sal, rubberwood, WPC, steel |
| Main door frame | 125 × 70 | 15–18 mm | Anchor fasteners to RCC/wall | Teak, sal, hardwood, steel |
| Bathroom door frame | 100 × 65 | 15 mm | Screws to plug; sealed base | WPC, granite, steel (no timber base) |
| WPC frame (readymade) | 100 × 60 | 15 mm | Screws to plug | WPC — water-safe throughout |
| Pressed steel frame | Profiled 100–125 | Formed | Grouted / welded lugs | GI steel, factory-primed |
Shutters: types, thickness and construction
Most doors today are flush shutters — a hollow or solid core faced both sides with plywood, then finished in laminate, veneer or paint. A flush shutter is dimensionally stable, takes any finish and suits mass production, which is why it dominates Indian homes. Panelled shutters, with solid stiles and rails framing timber or glass panels, are chosen for main doors and heritage looks; moulded skin doors press a wood-grain panel profile into a hardboard face over a frame, giving a panelled appearance at a lower cost. Thickness follows duty: 30 to 32 millimetres for internal and bathroom leaves, 35 millimetres for a good bedroom door, and 35 to 40 millimetres for a main door that must feel solid and carry a mortice lock.
| Shutter type | Core | Typical thickness | Best finish | Best for |
|---|---|---|---|---|
| Flush (solid / block core) | Block board / solid | 32–35 mm | Laminate, veneer, paint | Bedrooms, main doors, heavy use |
| Flush (tubular core) | Hollow stiles + battens | 30–32 mm | Laminate | Stores, light internal doors |
| Panelled (timber) | Stiles, rails, panels | 35–40 mm | Polish, PU paint | Main doors, traditional looks |
| Moulded skin door | Frame + hardboard skin | 30–32 mm | Factory paint | Budget bedroom doors |
| WPC / PVC shutter | WPC board / foam core | 28–32 mm | Lamination, paint | Bathrooms, wet areas |
Clearances, gaps and tolerances
A door that fits perfectly on paper still fails if the gaps are wrong. The working gap on the hinge and lock sides is about 3 millimetres, enough for the leaf to swing without binding when timber swells in the monsoon. The gap under the shutter is set by the floor finish: roughly 10 to 12 millimetres over bare screed before tiling, trimmed to about 8 millimetres over a finished tile floor, and increased to 15 to 20 millimetres where a rug or a bathroom threshold must pass beneath. Beyond the leaf itself, the swing needs clear floor: a 900 millimetre door sweeps a quarter-circle of 900 millimetre radius, and furniture or a light switch must sit outside it.
| Clearance | Typical gap | Why it matters |
|---|---|---|
| Hinge and lock side gap | 3 mm each | Lets the leaf swing without binding when timber swells |
| Gap under leaf (tiled floor) | 8–12 mm | Clears the floor; allows air transfer to the room |
| Gap under leaf (with rug/threshold) | 15–20 mm | Passes a rug, mat or bathroom threshold strip |
| Frame to masonry packing | 10–15 mm all round | Space to plumb and pack the frame true |
| Swing arc to furniture / switch | ≥ 50 mm | Stops the leaf fouling a bed, switch or second door |
Materials and indicative costs
Prices below are indicative October 2026 ranges, excluding GST, and vary widely with timber grade, finish and city; they should be confirmed with a local carpenter or supplier before budgeting. A frame is usually priced per running foot of section, and a standard bedroom frame uses roughly 17 running feet (two jambs of about 7 feet plus a 3 foot head). Shutters are priced per leaf, finished. The spread is large because a plain laminated flush door and a seasoned teak panelled door are different products that happen to share an opening.
| Item | Indicative cost | Notes |
|---|---|---|
| Hardwood frame (sal / other) | ₹350–750 per running ft | Bedroom frame ≈ ₹6,000–12,000 fitted |
| WPC frame (readymade) | ₹250–450 per running ft | Water-safe; good for bathrooms |
| Pressed steel frame | ₹3,500–7,000 per frame | Durable; common in institutional work |
| Flush shutter, both-side laminate | ₹1,800–3,800 per leaf | The everyday bedroom door |
| Flush shutter, veneer + polish | ₹3,800–7,500 per leaf | Warmer look; needs care, stays dry |
| Moulded skin door (painted) | ₹2,500–5,000 per leaf | Panelled appearance, budget price |
| Solid teak panelled door | ₹18,000–45,000+ per leaf | Main doors; seasoned, heavy, long-lasting |
| WPC / PVC shutter | ₹2,200–4,500 per leaf | Bathrooms and wet areas |
Hardware sized to the door
A door is only as good as the hardware that hangs and holds it, and hardware is sized to the leaf, not bought by habit. Hinges carry the weight: a light internal leaf runs on three 100 mm butt hinges, while a heavy main door needs four, and on a tall or solid leaf the hinges should be rated for the actual weight rather than assumed adequate. The lock follows the use — a cylindrical or tubular latch for a bedroom, a mortice lock for the main door, and a privacy latch or a simple bolt for a bathroom. Each lock type needs a specific backset and a cross-bore or mortice pocket, which is why the lock is chosen before the shutter is drilled, not after it comes to site.
Two fittings quietly decide how a door behaves day to day. A door closer or a soft-close device stops a main door slamming in the monsoon draught, protects the frame and takes the strain off the hinges, extending the life of the whole assembly. A door stop — floor-mounted or wall-mounted — keeps the handle from punching the wall and the leaf from over-swinging past its hinges. Weatherstripping and a threshold seal on the main door cut dust, draught and the band of light under the leaf. None of this is costly, but leaving it to chance is why so many doors droop, bang and mark the wall within a year of a careful fit-out. A door should be specified as a set — frame, shutter, hinges, lock and stop together — so that nothing in the chain is the weak link.
| Door | Hinges | Lock | Extras |
|---|---|---|---|
| Main / entrance | 4 heavy / ball-bearing | Mortice lock | Closer, stop, weatherseal |
| Bedroom | 3 butt (100 mm) | Cylindrical / tubular latch | Door stop |
| Bathroom / WC | 3 butt (100 mm) | Privacy latch or bolt | Under-leaf vent gap |
| Store / utility | 2–3 butt | Simple latch or pad bolt | — |
Where door design is heading
Three shifts are visible in Indian door practice. The first is the move to taller, frameless-looking leaves: doors run to 2250 or 2400 millimetres with slim concealed frames and no visible architrave, so the door reads as a flush plane in the wall. The second is the spread of engineered, water-stable materials — WPC, HDHMR and metal frames — replacing solid timber in bathrooms and humid coastal homes, where the old chowkat always failed first. The third is hardware: concealed hinges, soft-close pivots and magnetic latches that let a door sit tight without a visible frame rebate. None of these changes the brief. A door must still clear the opening, swing freely, seal reasonably and carry its hardware for decades — the sizes in this article remain the test every new detail has to pass.
Rules for specifying a door
- Fix the three sizes together: masonry opening, frame outer and shutter clear width — never quote one and assume the rest.
- Hold the height at 2100 mm unless a taller leaf is a deliberate design decision, and keep every door in the home to the same height for a clean line.
- Keep clear widths to NBC minimums or above: 900 mm for habitable rooms, 750 mm preferred for bathrooms.
- Match shutter thickness to duty — 35–40 mm for main doors, 32–35 mm for bedrooms, 30–32 mm for bathrooms and stores.
- Use a water-safe frame (WPC, steel, or timber on a stone base) in every bathroom and in coastal homes.
- Specify a solid hardwood lipping on all four shutter edges so the door can be trimmed and holds its lock screws.
- Set the 3 mm side gaps and the under-leaf gap to suit the final floor finish, not the bare screed.
- Draw the swing arc on the plan and keep furniture, switches and a second door out of it.
- Size hinges and the closer to the leaf weight, and use four hinges on any heavy main door.
Frequently asked questions
What is the standard door size in India?
The near-universal standard is 2100 mm (7 ft) high. Main doors are 1000–1200 mm wide, bedroom and kitchen doors 800–900 mm, and bathroom doors 600–750 mm, with 750 mm preferred. These are shutter clear widths; the frame and masonry opening are larger.
What is the size of a door frame (chowkat)?
A common internal chowkat section is 100 × 65 mm; a main door frame is heavier at about 125 × 70 mm. Each has a rebate cut about 15 mm deep for the shutter to close into. A standard bedroom frame uses roughly 17 running feet of this section.
How thick should a door shutter be?
Thickness follows duty: 35–40 mm for a main door, 32–35 mm for a bedroom door, and 30–32 mm for bathroom, store and utility doors. A thicker leaf feels more solid, holds a mortice lock better and resists warping.
What is the minimum door width as per NBC 2016?
NBC 2016 Part 3 sets a minimum clear width of 900 mm for a habitable-room door and 750 mm for a bathroom or water-closet door. These are minimums for usability and escape; comfortable practice often exceeds them, especially for the main entrance.
Which door is best for a bathroom in India?
A WPC or PVC shutter on a WPC or steel frame, since both resist water and will not rot or swell. If timber is preferred for looks, the frame should sit on a short granite or stone base block so the wood never touches a wet floor.
Sources & standards
- Bureau of Indian Standards — IS 4021: Timber door, window and ventilator frames
- Bureau of Indian Standards — IS 1003 (Part 1): Timber panelled and glazed shutters; IS 2202: Wooden flush door shutters
- National Building Code of India 2016, Part 3 — Development Control Rules and General Building Requirements (door widths and heights)
- National Building Code of India 2016, Part 6 — Structural Design, and Part 8 — Building Services (fittings and materials)
- Neufert, Architects' Data — standard door and frame dimensions and clearances
- Time-Saver Standards for Architectural Design — door schedules and hardware
- Price ranges: indicative October 2026 estimates — confirm locally before budgeting



